AB-R12F

P.R.P. Prime Power-Continuous power at variable load:

The power that a genset can

supply in continuous service at a variable load for an unlimited number of hours per year

while respecting the maintenance intervals established in the environmental conditions

stated by the Manufacturer. according to ISO8528-1. The average power supplied over time

and any applicable overload must be less than the percentages stated by the Manufacturer.

L.T.P. Limited-time running power-Limited power:

The maximum power that a genset

can supply for a limited time respecting the maintenance intervals established in the

environmental conditions stated by the Manufacturer according to ISO 8528-1.The number

of hours per year is stated by the Manufacturer. Overload is not permitted.

Description

MAIN DATA Article No.: 1260001
Continuous power (PRP) 11.0 (KVA)
Continuous power (PRP) 8.80 (KW)
Stand-by power (LTP) 12.10 (KVA)
Stand-by power (LTP) 9.70 (KW)
Voltage • Frequency • Power Factor 230V •50Hz • 1 cosφ
Sound press. (at 7m) N/A dB(A)
DIMENSIONS AND WEIGHT
Width 900 mm
Length 1400 mm
Height 975 mm
Weight 450 Kg
< Return to Catalog